User Messages
1. Connectivity and Routing Issues
Routing process cannot start.
Routing process was interrupted.
Navigation cannot start.
Make sure you are working in a valid context.
The start element does not have a free connector.
The End element does not have a free connector.
Neither the start nor the end elements have a free connector.
The start connector is either blocked or inaccessible.
The end element/connector is blocked, inaccessible from the selected branch direction, or the end segment length is not enough for required fittings.
Start connector is blocked.
End element/connector is blocked.
The end element is inaccessible. Make sure that the path between start and end elements is not blocked.
2. Valid Element and Selection Errors
Please select a valid element. Plumbing-Copilot only supports pipes, pipe fittings, and MEP equipment/fixtures.
The start and end elements cannot be the same element.
First selection is invalid.
Second selection is invalid.
Pipe insulation is not a valid element. Please hide the 'Pipe insulations' in the Visibility/Graphics menu and try again.
The selected start element does not have a valid system type.
The selected End element does not have a valid system type.
The start or end element is not properly contained within a routing element.
The {start/end} element is not properly contained within a routing element.
3. System and Family Assignment Issues
No 'Transition' family is assigned for the current pipe type {PipeType.Name} and the pipe sizes of the start, end, or both elements.
No 'Elbow' family is assigned for the current pipe type {PipeType.Name} and the used pipe size.
Navigation cannot start. The 'Junction' family assigned for the current pipe type: {PipeType.Name} and the used pipe size cannot be used.
Transitioning between the two sizes is not possible for the following element: {Element.Name}.
WARNING! The 'Junction' family assigned for the current pipe type: {PipeType.Name} and the used pipe size ONLY supports Tee-type junctions.
There is no 'Junction' family assigned for the current pipe type: {PipeType.Name} and the used pipe size.
4. Slope and Height Issues
The current height difference is insufficient to connect the elements using sloped pipes.
Sloped pipes can't be used to connect two elements at the same height.
Make sure the start element doesn't have a slope.
Make sure the end element doesn't have a slope.
Make sure the end element is not tilted.
The height difference is insufficient to connect the elements using sloped pipes with connection type: {Tee/Wye} and connection direction: {Up/Down/Side}.
The end element is inaccessible. Ensure the path between start and end elements is not blocked.
5. Project Issues
Can't find any valid level in the project. Please ensure that there is a floor plane defined for the level you are currently working on.
There must be at least one piping system in the project.
6. License and Login Issues
Login to start using Plumbing-Copilot. Please ensure you are connected to the internet.
Your license is not valid.
Last updated